Hi All!Upgraded to Creo 3.0 m050 and Windchill 10.2 m030 a couple of weeks ago. Now when I add an instance to the family table it insists: "To save this generic, the entire family table must be...
View ArticleAPI to get List of Attributes from WTPart
Hi All, I am using below code to fetch IBA values for WTpart,but in this program i have to give input as IBA name.i want all IBA for that part which having any value or null,as shown here fig....
View ArticleHow do i change an inherited attribute's contraint?
Hello all, This may have already been posted somewhere, but I could not find anything on it. I have performed a subtype of Part in the Types and Attribute Manager. I now have two issues that I cannot...
View ArticleLicence clarification
Hi. Can anybody please confirm whether the following licenses come free with the system or whether they come from the pot of Print & View and Heavy user that one purchases: Site...
View ArticleStructure View of an Instance
How do you expand all levels of the structure for a Part Instance without having to click on each level to open them up?
View ArticleCompare 2 Revisions of an Instance
When completing a compare of 2 revisions of an instance, it will not show anything below a serialized component nd also will not compare the serial number attributes. Is there a way to get Windchill...
View ArticleSet custom UOM while creating a new Part with using code.
I have custom UOM in Windchill loaded to QuantityUnitRB, but I am not able to create a new Part with custom UOM using code. getting the values via QuantityUnit[] qu = QuantityUnit.getQuantityUnitSet();...
View ArticleWhich Windchill api to determine if object is new in workspace?
Windchill 10.2 M030I am looking an api to determine if a wtpart or epmdocument is new in the workspace. Anybody have any pointers? Thanks Randy
View ArticleFault Tree Analysis - WQS (Relex)
I have created a number of fault trees, set parameters and run the FTA model. I have my FTA results. I wish to see the cut sets of my fault tree and have used the highlight cut sets feature. Relax...
View ArticleHow to set up a Windchill PDMLink test system
Hi everybody, I need to set up a Windchill PDMLink test system. So I´m trying to install windchill on a local machine (don´t want to touch the prod server ).As manual serves this...
View ArticleWindchill 10.2 servers stop
Hi, I am new in windchill 10.2I installed the windchill servers on a windows 2012 r2 server without windows services I wonder how to stop properly the windchill servers (HTTP server, method server,..)...
View ArticleDoes anyone know how to send out automatic emails after an account is created...
All, We want automatic emails to go to the people whose accounts were just created in Windchill. Does anyone know or has a process designed? Thanks,Mitch
View ArticlePDMLINK vs MPMLINK ?
Hi, I would like to know the differences between PDMLINK and MPMLINK I have been told MPMLINK is a layer above PDMLINK, but i am not sure regardsLaurent
View ArticleDisplay Mass Properties from Search
Is there a way to display mass properties of CAD documents from a list of part numbers? I have a list of numbers and can search/display them in windchill but would like to display the mass of each as...
View ArticleSecurity update for IE11 -- Creo Parametric WGM Issue
I am getting multiple reports from users with WGM (IE11 browser type) issues (lockups, spinning wheel, check in issues) after a Windows update with CP3 M030. Setting browser type to Chromium resolves...
View Articlenx won't open in creo parametric 3.0 m050
Is anybody having issues opening NX 7.5 files in Creo 3.0 M050/Windchill 10.2 M030? If an NX file is opened from a workspace Creo session fails. If that same file is opened from a folder location on...
View ArticleSecret/Secure projects
Hi all, I'm looking for some advice on strategies for handling design work in our company that needs to be kept secure/secret from all users except those specified as having permission to access it....
View ArticleSearch for Generic and or Instance in Intralink 10
I am trying to find lost vendor components that need to be moved to the library. Most of these are family table related. Is there a way to search for generic/Instance/family table in intralink 10?
View Articleshared team
Hi, i would like to understand the "shared team" concept in Windchill regardsLaurent
View ArticleWindchill Naming Problems
Windchill does not allow me use the same part number for my part/assembly to name my drawing file. I have been using Pro/E for over 15 years, and have never had this problem. Can someone help me out to...
View Article