Unable to register Creo and Auto CAD with PDM Essentials 10.2 M030
Hi all, I'm trying to integrate Creo 3.0 M080 and Auto CAD 2016 with Windchill PDM Essentials 10.2 M030 (CPS13) but getting error " Invalid server location".We've Windchill url like...
View ArticleHow to integrate E3 ECAD with Windchill?
Dear All CAD experts,Can anyone let me know how to integrate E3 ECAD toll with windchill?Is it possible through WGM ?
View Article2015)?">“Update Worker" for data managed in Windchill (e.g. Solidworks 2014 -> 2015)?
As Solidworks needs to convert files to the new file format after a major version upgrade to ensure performance and stability we thought about the need to have an “Update Worker” to convert at least...
View ArticleError after updating from 10.2 M020 to M030: "Data marked not to be...
Hi! After updating from Windchill PDMLink 10.2 M020 to 10.2 M030 we have issues concerning the publisher.The goal is to open Creo View with the default representation of a specific EPMDocument. This is...
View ArticleError While opening CATIA Model in WGM
Hi,When i try to open a CATIAV5 Model from PTC WGM. i am getting error "Download failed : NO PERMISSION to Download the CAD Document". The same error i am getting if try to open the model from CATIA or...
View ArticleWindchill cluster and vault connected to two hosts? what type of vault...
few questions: slave and master BOTH must have windchill vault connected?what type of storage on windows vmvare will work for this purpose? Thanks, Adriana
View ArticleWindchill Relationtionship Report SQL SELECT
I would like to produce a Windchill relationship text-file report for all Pro/E CAD Documents (epmdocument), using an SQL SELECT statement (Oracle).The output would include the following info:DOCTYPE,...
View ArticleAltuim and the WGM
Hello Everyone,We have purchased a handful of the Altium Workgroup Managers. We are currently running Windchill 10.2 M020 with latest CPS. I have been unsuccessful at bringing anything from Altium...
View ArticleAnyone using the ESI-TIBCO Integration to transfer Effectivity controlled...
We currently use the ESI-TIBCO integration to send WTParts and eBoMs to SAP (latest Released).We are investigating effectivity in Windchill and would like to know if ESI-TIBCO could be configured to...
View ArticleSQL Server 2012 can be shared between Windchill 10.2 and Integrity 10.9
I am planning to install Windchill 10.2 with SQL Server 2012 as backend database. I have SQL server 2012 which already installed for Integrity 10.9 with ‘Latin1_General_CI_AI’ collation. So I created...
View ArticleHow to I restore a Project backup file (*.BAK)
How do I restore a Project's backup file (*.BAK) from the backup directory as listed/stored in the Project's Backup's directory? These are the BAK files sitting in the Backups folder, however, I cannot...
View ArticlePart and Cad Document are out of date
Anybody know what causes this message? it appears from the reference document that it references the correct versions. Thanks in advance!
View ArticleFMEA Error
When accessing a project system and I modify my FMEA worksheet using the Format Builder, at times some weird and wonderful things happen and when I go to access/open the system file again and have FMEA...
View ArticleProblem when trying to disable "remove" button
Hi everyone, I have to make a custom filter to deactivate some buttons when the root part (here the green/yellow cog) was on a specific state.And when I select the other sub part (pink cog) the button...
View Articlemass edit attributes for WTDocument no convinient in 10.2
In Windchill 10.2, Edit multiple objects can mass edit an attribute, but however, for WTdocument, you have to click the radio box "do not upload file" for each item you select. This is unacceptable...
View ArticleCan we add an Attribute of a Sub type of WTDocument which is an optional and...
Hi All, Can we add an Attribute of a Sub type of WTDocument which is an optional and single valued string attribute which can have only one amongst the suggested values and no other values should be...
View ArticleHow to validate Create Page Attributes
Hi, I am working on one UIValidation where I need to validate the two attributes (customer part number, new customer part number ) of New Document wizard page, currently I am trying this is on...
View ArticlePart Association Image No Visual
One assembly is an Image association to the other. From what I understand no attributes are passed from image item to wtpart, but in a product structure the Visual, or image, should remain. What I...
View ArticleWindchill upgrade log files?
I finally have a commitment from management and our IT-Group to move forward with our Windchill/IntraLink 10.2 and Creo 3.0 upgrade from Intralink 3.4 as soon a June. I have already done a few test...
View ArticleWindchill Migration services?
I’m sure with my last post and this one my phone will soon be ringing off the hook? I have been tasked again to explore and select a re-seller to perform our migration. (I did this last August but was...
View Article