Quantcast
Channel: PTC Community : Unanswered Discussions - Windchill
Viewing all 3592 articles
Browse latest View live

Edit From Palette

$
0
0

Hi,

 

Is there a property in FlexPLM, that can be set to allow users to mass update/edit the materials from the Palette in 9.2 or 11 ? I see a button that says Edit Table, but when selected nothing happens.

 

Palette.JPG


LiveCycle delegate for custom ddx watermarking

$
0
0

Hi all,

 

I am trying to implement a custom LiveCycle delegate to generate different ddx files based on the state of the WTDocument.

Without the custom hook the watermarking works (ddx added to visualization configuration) based on what is described in the help . In the same help file it is described how to configure a custom delegate, but based on that tutorial I can't get it working. My custom code is not called upon publishing. I have 10.2 M30 system and the worker with Adobe LiveCycle server is on a remote machine.

 

Any tips on this topic? Is there some additional step which is not described on the support page?

 

Thx,

Tamás

How to get the representation on Parts from the CAD document associated with owner link without using the build process ?

$
0
0

Our Parts and CAD structures are not synchronized but some nodes are linked with owner links. I would like to get the representation on Parts without building the Part structure.

Create a customized view and share with a particular group as similar to functionality in Saved Search

$
0
0

Refer to the screenshots for more information

Failure to laod native dll [wppndmerge.dll] in WBMFF

$
0
0

I am trying to configure WBM 11.0 into my local system. but getting error "Failure to load native dll" from Settings.txt file

Below is the entry has been provided in Settings.txt also the PATH to the wppndmerge.dll been provided.

 

## 5. specify CAD adapter Dll path

# for Creo

creoAdapterDllPath=C:/Program Files/PTC/Creo 3.0/M100/Common Files/x86e_win64/obj/wppndmerge.dll

 

Error Details:

*** Terminating exception (ProcessCADFiles):

com.ptc.windchill.migration.wbm.wbmff.util.WbmffException: Failure to load nativ

e dll: C:/Program Files/PTC/Creo 3.0/M100/Common Files/x86e_win64/obj/wppndmerge

.dll

        at com.ptc.windchill.migration.wbm.wbmff.cad.CreoCADProcessor.startAdapt

er(Unknown Source)

        at com.ptc.windchill.migration.wbm.wbmff.cad.CreoCADProcessor.configure(

Unknown Source)

        at com.ptc.windchill.migration.wbm.wbmff.cad.CADProcessor.configure(Unkn

own Source)

        at com.ptc.windchill.migration.wbm.wbmff.cad.CADOperations$7.execute(Unk

nown Source)

        at com.ptc.windchill.migration.wbm.wbmff.util.ActionsHelper.executeList(

Unknown Source)

        at com.ptc.windchill.migration.wbm.wbmff.cad.CADOperations.execute(Unkno

wn Source)

        at com.ptc.windchill.migration.wbm.wbmff.util.ActionsHelper.configureExe

cuteClose(Unknown Source)

        at com.ptc.windchill.migration.wbm.wbmff.CADFiles$CADFilesContext.rootEx

ecute(Unknown Source)

        at com.ptc.windchill.migration.wbm.wbmff.Context.execute(Unknown Source)

 

 

        at com.ptc.windchill.migration.wbm.wbmff.OperationDispatcher.commonMain(

Unknown Source)

        at com.ptc.windchill.migration.wbm.wbmff.WbmFromFiles.main(Unknown Sourc

e)

Exiting WbmFromFiles, exit code: 1

How do I make Windchill read only?

$
0
0

We are retiring Windchill Intralink 9.1 soon, and migrating to a different PDM.
However, we want to keep Windchill running as read-only for a few months in case we discover any files that were not migrated.

My first thought was to make all vaults read-only. But is that enough?

Will users still be able to revise, check-out, or promote?
All we want is for users to be able to "Add to Workspace" in Pro/E so they can export afterward.

I'm hoping to avoid using the Policy Administrator to change Domain permissions.

(It's been years since I've created/changed those.)

 

Gerry Champoux

Williams International

How to not display family table instances in Windchill

$
0
0

Hi,

 

I added this part in my Windchill 10.2 workspace from a family table and it occurs that this family table is pretty big.

Is there a way to only display the generic part and not see the whole list in my workspace, or only the instance I use?

 

My assembly have something like 10 parts but they are flooded in 300 instances of a screw...

A workflow is getting terminated when the object is in checked out state. How to avoid workflow termination

$
0
0

Workflow gets terminated when the user clicks on complete task while keeping the object is in checked out state. How to avoid the workflow termination? Would like to give a warning message to the user that object is in checked out state and previous activity should work. Please let me know how to do this.

 

Thanks in advance


how to change the layout of a report in windchill

$
0
0

I would like to generate a report which contains only object name and object number at the top remaining lifecycle history with comments below. Can anyone help me on this?

MPMLink

$
0
0

My company, due to market conditions, is looking into MPMlink.  Since we are using Windchill PDMlink, we naturally are looking at MPM to help transform BOMs.  I would like to hear from companies that are currently using this module: likes, dislikes, issues, and any things we should consider as we interrogate if this would be a good solution for us.  We have very large BOMs (build custom snow removal chassis), and we are 80% CTO with the remaining 20% ETO.

 

PDM: 10.2 M030 CPS 17

We are using WTparts and Options & Variants

 

Thanks,

Greg

Upload with a specific revision

$
0
0

We currently have Windchill setup so that a new document when uploaded is set to be at Rev A. In some cases, we need the initial revision to Rev 0.

Is there a way to specify the default revision in the OIR with an option on the New Document form to override the default Rev A?

 

Windchill 10.0 m040.

WWGM change defaults in Windchill

$
0
0

When the Windchill Workgroup Manager was installed with Windchill various choices were made. Now that we have developed a silent installer we are delivering via LANDesk, it appears some of the choices they made when installing it were not what we want.

 

Is there some way of changing these choices either by editing the files output from Windchill for the silent install, or by editing what's in Windchill itself?

 

Specifically we'd like it not to try to auto register apps.

Windchill 11.0 Bug?

$
0
0

Hi all,

 

We are planning to go to Windchill 11.0 M010 CPS02.

 

We noticed that eventhough when we make the following setting in the OIR for NUMBER to be unchangeable.,

 

<AttrConstraint id="number" algorithm="com.ptc.core.rule.server.impl.GatherAttributeConstraints">

 

<Value algorithm="com.ptc.core.rule.server.impl.GetImmutableConstraint"/>

 

</AttrConstraint>

 

 

It Does not Work!!

 

PTC call is opened, but taking some time..

 

Thanks

Hari

Replace number field with picker

$
0
0

Hi.

I need to build WTPart number in create wizard based on some classifier. Classifier item should be selected by user through picker.

So i created datautility that uses PickerInputComponent.

But now PickerInputComponent's input field has no binding to wtPart number. Windchill considers number as null and generates itself.

PickerInputComponent.setId() and PickerInputComponent.setColumnName() do not solve problem.

What can i do?

May be should i use another approach to solve problem?

Thanks.

sql link "modified by" and wtpart(master)

$
0
0

Hi,

 

Does somebody know in which table I can find the "modified by" for a wt.part.WTPart?

And maybe the link with the table wtpart or wtpartmaster?

 

Thanks in advance

kind regards

Ruben


Finding objects checked out by disconnected users

$
0
0

How can I find all the checked out objects by a disconnected user.  I cannot set up a search for this because the disconnected user has been deleted and cannot be used in the search criteria.   

Unable to do a set state?

$
0
0

I am not able to do a set state

Here is the error I have in event management

Validate_F53A550002-2D.drw.jpg

Showing the BOM Filter currently Used

$
0
0

Hi all,

 

Wont it be handy to show to the user on what was the BOM Filter currently used to render the BOM? (Part structure).

 

It is often necessary to see BOMs with Baseline filter, and it is difficult to know which baseline filter used to render.

 

Preference / Properties?

 

We are in WC 11.0 M010.

 

Thanks

Hari

External access to the windchill system

$
0
0

Hi guys,

 

 

Need free access of users windchill system outside the network of my company, what would be the best practice for this type of access so as not to compromise system security?

 

 

Thank you for your help,

How to import excel to list library

$
0
0

Dear,

 

For the FMEA within our company we have an excel sheet with a lot of FM.

I would like to import this excel sheet into a list library.

 

From reading in the forum I see that this is possible with FRACAS. But we don't have the FRACAS module.

 

Is there a possibility to solve this using Excel?

 

 

Thanks in advance!!

 

 