Windchill Server Status - Site Not Responding?
Hi all, I've recently installed an monolithic instance of Windchill 10.1 M040 (SQL Server) and have spent several weeks tailoring it to our requirements, testing workflows & lifecycles document...
View ArticleGHOSTS! - ooooh scary! Pain in the @ss
To All, We have been experiencing issues with ghosts objects for quite some time now and PTC does not appear to have any idea how to resolve them. Point is the "Autoresolve" check box on the second...
View ArticleFTA Exposure Time Question
When I want to specify an exposure time that is shorter than the flight time in an SAE fault tree. Do I divide the time by flight time, or 1 hour. Ex. my exposure time is 3 minutes, my Flight Time is...
View ArticlePublish existing WTParts through load file
We have WTParts which are associated with distribution targets and need to publish these parts through load file.We are using Windchill 10 Below is the procedure we followed to customize this. 1. Made...
View ArticleSharing Documents to ProjectLink
How can we ensure that documents “SHARED” to a project from PDMLink , does not get updated when the document undergoes a change in the PDMLink. I would update the dcoument share in PJL manually when...
View ArticleUsing SequenceGenerator in code
Hi, all.I need to use SequenceGenerator for WTPart in java code.I have tried setNumber(SequenceGenerator.generateValue("WTPARTID_seq")) but result was not i expected to see.Now i am trying...
View ArticleError on Save As action for Windchill 10.2 M010
Hi, I am getting nullpointer exception while performing Save As action from all the places in PDMLink. Save As window remains grade out and gather object table does not get initialized. any help would...
View ArticleRemote Completion of Workflow Tasks via Email
Is there a way to allow users to complete workflow tasks (e.g., approve a promotion request) via email (i.e., have a hyperlink in the email message for approve, reject, etc. that would complete the...
View ArticleHow to get Workitem?
Hi all, I'm editing Variance Workflow via Workflow Manger. I have the PrimaryBusinessObject variable. But how can I get the appropriate Workitem object? Thanks a lot
View ArticleWizard table and add action
Hi.I have a constructing wizard problem.I need add a collection of persistable objects (that are exist already) to document creation wizard.I suppose to create a table (at a certain wizard step) to...
View ArticleOld version/rev. of part in assembly?
Does anyone know if Pro/E allows a user to add an old revision/iteration of a .prt to an assembly? I have been able to add rev. A of a part that is at rev. B in Windchill. Is there a way to select...
View ArticleBackgroundMethodserver
I have configured BGMS in my server. Now when I am trying to start windchill either, MS or BGMS is starting but not Both. One of them will just blink and goes off. What might be the reason for this.?...
View ArticleImporting Documents (PDFs) into PDM Essentials
We have been using WindChill PGM Essentials now for a few months. I cannot seem to figure out how to upload/import non CAD files into common space. This software is supposed to be able to complete...
View ArticleWindchill deployment on Cloud
Hi All, Need your advise and recommandation to deploy Windchill on Cloud platform( Amazon EC2). If you have experience any deployment difficulties pl.let me know. Also is there major installation...
View ArticleHow to give restriction on .dll file storage in windchill 10.1
Hi, I want to give restriction on file storage for .dll file types. So that all our users are restricted in storing .dll files on the windchill server. Regards,Chirag
View ArticleI need to check out an older version.
I need to check out an older version of several files. Can I do this in Intralink 10.1 and how do I do it? Thanks in advance,Steven
View ArticleDownload documents to compressed file
Hi Fellows, When I use the "Download documents to compressed file" on a search result I only get the Primary contents.Is it also possible to download the attachments? I'm working on Windchill PDMLink...
View ArticleInstallation problem - windchill 10.1 M040
Hi, During installation of Windchill PDMlink 10.1 M040 with Oracle 11g R2, it is failing with error message "Windchill loader failed'. Can any one support on this issue.
View Articlewindchill PDMlink versions / features
Where do I find the details of the difference between the windchill PDMlink versions / features.
View ArticleFind WTPart by EPMDocument
Hi.I have WTPart and EPMDocument linked by EPMDescribeLink.How can i find WTPart by EPMDocument in this case?I can't see any useful methods in WTPartHelper.service or EPMDocumentHelper.service.Thanks.
View Article